Medium temperatures MBP - HBP compressors for R134a Temperature range from -25°C till +15°C
Model
Cooling capacity tevapor. =-10°C - tconden. =+45°C (EN12900)
Displacement cm3
EMT6144Z
294 W
5.20 cm3
EMT6160Z
377 W
6.76 cm3
NEK6170Z
422 W
8.40 cm3
NEK6187Z
477 W
10.00 cm3
NEK6210Z
578 W
12.12 cm3
NEK6212Z
665 W
14.30 cm3
NEK6214Z
752 W
16.80 cm3
NT6215Z
796 W
17.40 cm3
NT6217Z
938 W
20.40 cm3
NT6220Z
1011 W
22.40 cm3
NJ6220Z
1114 W
26.10 cm3
NJ6226Z
1497 W
34.40 cm3
NJ6226ZX
1644 W
34.40 cm3
Low temperatures LBP compressors for R134a Temperature range from -40°C till -10°C
Model
Cooling capacity tevapor. =-35°C - tconden. =+40°C
Displacement cm3
EMY3111Z
62 W
4.50 cm3
EMY3115Z
163/171 W (Cooling capacity tevapor. =-23.3°C - tconden. =+54.4°C)
6.10 cm3
NEK1118Z
111 W
8.40 cm3
NE1121Z
124 W
9.30 cm3
NE1130Z
161 W
12.10 cm3
NE2134Z
179 W
14.30 cm3
NEK2140Z
217 W
16.80 cm3
Medium temperatures MBP - HBP compressors for R404a Temperature range from -25°C till +15°C
Model
Cooling capacity tevapor. =-10°C - tconden. =+45°C
Displacement cm3
EMT6144GK
378 W
4.00 cm3
EMT6165GK
484 W
5.20 cm3
NEK6165GK
542 W
6.20 cm3
NEK6181GK
599 W
7.30 cm3
NEK6210GK
724 W
8.78 cm3
NEK6213GK
972 W
12.12 cm3
NEK6217GK
1166 W
14.30 cm3
NT6220GK
1096 W
14.50 cm3
NT6222GK
1287 W
17.40 cm3
NT6226GK
1752 W
22.40 cm3
NJ9232GK
1911 W
26.10 cm3
NJ9238GK
2424 W
32.70 cm3
NJ9238GS
2506 W
32.70 cm3
Mentioned above equipment is equipment, whose functioning relies upon fluorinated gases
Low temperatures LBP compressors for R404a Temperature range from -40°C till -10°C
Model
Cooling capacity tevapor. =-35°C - tconden. =+40°C
Displacement cm3
EMT2117GK
141 W
4.50 cm3
EMT2125GK
204 W
5.96 cm3
NEK2134GK
253 W
8.78 cm3
NEK2150GK
346 W
12.12 cm3
NEK2168GK
380 W
14.30 cm3
NT2178GK
420 W
17.40 cm3
NT2180GK
490 W
20.40 cm3
NT2192GK
551 W
22.40 cm3
NJ2192GJ
585 W
26.10 cm3
NT2212GK
719 W
27.80 cm3
NJ2212GK Connection Rotalock or brazing
775 W
34.40 cm3
NJ2212GS
775 W
34.40 cm3
Mentioned above equipment is equipment, whose functioning relies upon fluorinated gases
Low temperatures LBP-L/MBP compressors for R600a Temperature range from -30°C till -5°C
Model
Cooling capacity tevapor. =--10°C - tconden. =+45°C (Cecomaf)
Displacement cm3
EMX20CLC
116 W
3.97 cm3
EMX32CLC
176 W
5.97 cm3
Medium temperatures MBP-HBP compressors for R290 Temperature range from -25°C till +15°C
Model
Cooling capacity tevapor. =-10°C - tconden =+45°C (EN12900)
Displacement cm3
EMT6144U
343 W
4.50 cm3
EMT6152U
418 W
5.20 cm3
NEK6181U
523 W
7.28 cm3
NEK6210U
640 W
8.78 cm3
NEU6212U
800 W
10.00 cm3
NEU6214U
944 W
12.12 cm3
NEK6217U
1018 W
14.30 cm3
NEU6220U
1317 W
16.80 cm3
NT6224U
1558 W
22.40 cm3
NT6230U
1937 W
27.80 cm3
Low temperatures LBP compressors for R290 Temperature range from -40°C till -10°C
Model
Cooling capacity tevapor. =-35°C - tconden. =+40°C (EN12900)
Displacement cm3
EMT2125U
177 W
5.96 cm3
EMT2130U
196 W
6.76 cm3
NEK2134U
271 W
10.00 cm3
NEK2150U
334 W
13.54 cm3
NEU2155U
364 W
13.54 cm3
NEU2168U
457 W
16.80 cm3
NT2170U
478 W
20.40 cm3
NT2180U
550 W
22.40 cm3
NT2210U
689 W
27.80 cm3
Low temperatures LBP-L/MBP compressors for R600a
Temperature range from -30°C till -5°C
Модель
Cooling capacity tevapor. =-10°C - tconden. =+45°C (Cecomaf)
Displacement см3
EMX20CLC
116 W
3.96 сm3
EMX32CLC
176 W
5.97 сm3
NB1118Y
427 W
14.28 сm3
Firma "Revers" LTD doesn't grant any warranties regarding the technical characteristics and parameters specified in this home page, and assumes no liability for any damages of any nature arising from the use of information provided here. Mentioned here Technical data and pictures are informative, and errors and misprints are not excluded.
This site uses cookies. By continuing to use this site, you agree to it.