Copeland EazyCool™ Outdoor Condensing Units

Copeland EazyCool™ Outdoor Condensing Units with Scroll Compressors

Model Cooling capacity on R404a, ambient temperature +32°C, boiling temperature= -10°C Receiver capacity (l) Number of fans Total motor power (W) Suction line Diameter (inch) Liquid line Diameter (inch) Length/Width/Height (mm) Net weight, kg

Motor version/Code

3*phase=TFD

1*phase=PFJ

Maximum operating Current (А)

3* phase

Sound Pressure 10м-d(BA)**

ZXME-020E 3.6 kW 4.4 1 116 3/4" 1/2" 424/1029/840 76 TFD/PFJ 4.9 (for 1PH 12) 39
ZXME-025E 1 PH 4.3 kW 4.4 1 116 3/4" 1/2" 424/1029/840 76 PFJ 12 (1*phase) 40
ZXME-030E 5.2 kW 4.4 1 116 3/4" 1/2" 424/1029/840 79 TFD 7.2 40
ZXME-040E 7.0 kW 4.4 1 116 7/8" 1/2" 424/1029/840 91 TFD 10.3 40
ZXME-050E 9.1 kW 6.3 2 246 7/8" 1/2" 424/1029/1242 108 TFD 12.8 41
ZXME-060E 10.4 kW 6.3 2 246 7/8"  1/2"  424/1029/1242 112 TFD 13.1 41
ZXME-075E 11.9 kW 6.3 2 246 7/8"  1/2"  424/1029/1242 118 TFD 14 42

 * 3 phases: 380-420 V/ 50 Hz

** 10m: sound pressure level at 10m distance from the compressor, free field condition

Conditions EN13215:Suction gas return 200C, Subcooling 0K

Model Cooling capacity on R404a, ambient temperature +32°C, boiling temperature= -10°C Receiver capacity (l) Number of fans Total motor power (W) Suction line Diameter (inch) Liquid line Diameter (inch) Length/Width/Height (мм) Net weight, kg

Motor version/Code

3*phase

Maximum operating Current (А)

3*phase

Sound Pressure 10м-d(BA)**
ZXDE-030E 5.3 kW 4.1  1 116 3/4"  1/2" 424/1029/840 79 TFD 6.7 39  
ZXDE-040E 7.6 kW 6.3  2 246 7/8"  1/2" 424/1029/1242 104 TFD 7.9 40
ZXDE-050E 9.0 kW 6.3  2 246 7/8"  1/2" 424/1029/1242 108 TFD 11.3 41
ZXDE-060E 10.5 kW 6.3  2 246 7/8"  1/2" 424/1029/1242 112 TFD 11.4 41
ZXDE-075E 11.9 kW 6.3 

2

246 7/8"  1/2" 424/1029/1242 118 TFD 14.0 42

 * 3 phases: 380-420 V/ 50 Hz

** 10m: sound pressure level at 10m distance from the compressor, free field condition

  Conditions EN13215:Suction gas return 200C, Subcooling 0K

Model Cooling capacity on R404a, ambient temperature +32°C, boiling temperature= -35°C Receiver capacity (l) Number of fans Total motor power (W) Suction line Diameter (inch) Liquid line Diameter (inch) Length/Width/Height (мм) Net weight, kg

Motor version/Code

3*phase

Maximum operating Current (А)

3*phase

Sound Pressure 10м-d(BA)**
ZXLE-020E 1.9 kW 4.4 1 116 3/4" 1/2" 424/1029/840 79  TFD 5.7 39
ZXLE-030E 2.6 kW 4.4 1 116 3/4" 1/2" 424/1029/840 81 TFD 6.7 40
ZXLE-040E 4.0 kW 4.4 1 116 7/8" 1/2" 424/1029/840 93 TFD 9.2 40
ZXLE-050E 5.0 kW 6.3 2 246 7/8" 1/2" 424/1029/1242 106 TFD 11.9 41
ZXLE-060E 5.8 kW 6.3 2 246 7/8" 1/2" 424/1029/1242 116 TFD 13.7 41
ZXLE-075E 6.5 kW 6.3 2 246 7/8" 1/2" 424/1029/1242 121 TFD 15.0 41

 * 3 phases: 380-420 V/ 50 Hz

** 10m: sound pressure level at 10m distance from the compressor, free field condition

  Conditions EN13215:Suction gas return 200C, Subcooling 0K

 

Firma "Revers" LTD doesn't grant any warranties regarding the technical characteristics and parameters specified in this home page, and assumes no liability for any damages of any nature arising from the use of information provided here. Mentioned here Technical data and pictures are informative, and errors and misprints are not excluded.